Resistor Color Code Flashcards: 4 Bands, 5 Bands & Tolerance

Practise 42 original resistor color-code prompts: decode and build conventional 4- and 5-band codes, calculate nominal tolerance intervals, and repair common errors.

За това тесте

Read the band roles before doing the arithmetic. These 42 resistor color code flashcards use written color names to practise conventional four- and five-band resistor markings.

You’ll retrieve band roles and selected color values, decode codes into nominal resistance and tolerance, and build codes from an explicit band count, nominal value and tolerance. Reverse encoding is a separate card task because it needs recall in the other direction. Short calculations cover ohms, kiloohms and megaohms; nominal tolerance intervals; exact hypothetical boundary checks; and local repairs for wrong roles, zero digits, units and premature rounding.

All ten significant-digit colors and all conventional multipliers, including gold ×0.1 and silver ×0.01, appear across the set. Tolerance questions deliberately cover only brown ±1%, red ±2%, gold ±5% and silver ±10%. Other tolerance colors exist; this is not an exhaustive modern tolerance table. Every code-conversion prompt states the conventional band count and left-to-right order. One uncertainty task leaves direction unknown and asks whether a unique reading is possible.

The sequence introduces band roles and simple decoding before fractional multipliers, reverse encoding and interval work. Later cards mix those skills with error repair and limits of identification. Closely related variants are kept apart; the review scheduler handles long-term spacing. Every card carries the resistor-color-code tag.

You should be comfortable with decimal multiplication and percentages. Interval tasks use exact hypothetical numbers and the inclusive model R × (1 − t) to R × (1 + t), where t is the tolerance percentage divided by 100. They do not teach measurement procedures or include measurement uncertainty. A marked nominal value is not an exact measured value, and tolerance is not a probability distribution or a guarantee under every operating condition.

Text-only prompts make the tested mapping explicit without requiring color discrimination. Visual color identification, automatic reversal of every lookup, leading-zero encodings, special manufacturer schemes, six-band temperature coefficients, component availability and real electrical repair are excluded. Extra permutations were omitted when they added no distinct recall task. This evergreen Electronics deck is not aligned to an examination or curriculum.

Band roles and the tested color facts were checked against Vishay’s resistor color-code chart. SI unit conversions follow the BIPM prefix definitions. Numeric exercises, wording and organization were independently authored. No manufacturer chart artwork, source examples, competitor cards, article exercises or examination questions were copied or adapted.

AI tools assisted with drafting and the original decorative cover. The author manually read every final front and back and checked each applied answer; this does not claim learner testing or measured learning gains. The CC0 dedication covers original wording, examples, organization, metadata and generated cover to the extent applicable rights exist. Facts and cited materials retain their own status. This is independent, unofficial study practice, with no affiliation to or endorsement by Vishay or the other referenced organizations.

Карти в това тесте

  1. Карта 1

    Въпрос

    In a conventional 4-band resistor code, what does each band mean from left to right?

    Отговор

    Two significant digits, multiplier, tolerance.

    Join the first two digits into one number, then multiply.

  2. Карта 2

    Въпрос

    In a conventional resistor code, what does a black band in a significant-digit position contribute?

    Отговор

    The digit 0.

    Keep it in the number. A zero digit does not make the whole resistance zero.

  3. Карта 3

    Въпрос

    Conventional 4-band code, read left to right: orange–white–brown–gold. Nominal resistance and tolerance?

    Отговор

    390 Ω ±5%.

    Orange–white gives 39; brown multiplies by 10. The final gold band gives ±5%.

  4. Карта 4

    Въпрос

    In the multiplier position of a conventional resistor code, what factor does black mean?

    Отговор

    ×1.

    A black multiplier leaves the significant-digit number unchanged.

  5. Карта 5

    Въпрос

    In a conventional 5-band resistor code, what does each band mean from left to right?

    Отговор

    Three significant digits, multiplier, tolerance.

    The third band is another digit; the multiplier moves to the fourth position.

  6. Карта 6

    Въпрос

    Conventional 5-band code, read left to right: red–black–blue–black–brown. Nominal resistance and tolerance?

    Отговор

    206 Ω ±1%.

    The digits are 2, 0, 6; the black multiplier is ×1. Final brown means ±1%.

  7. Карта 7

    Въпрос

    In the tolerance position of a conventional resistor code, what does gold mean?

    Отговор

    ±5%.

    This percentage describes a permitted deviation from the nominal resistance in the stated tolerance model.

  8. Карта 8

    Въпрос

    Can gold or silver be a significant digit in a conventional 4- or 5-band resistor code?

    Отговор

    No. Neither color represents a significant digit.

    Gold and silver are used for multipliers or tolerances in this scheme.

  9. Карта 9

    Въпрос

    In the multiplier position of a conventional resistor code, what factor does gold mean?

    Отговор

    ×0.1.

    Divide the significant-digit number by 10.

  10. Карта 10

    Въпрос

    Conventional 5-band code, read left to right: brown–red–white–brown–gold. Nominal resistance and tolerance?

    Отговор

    1.29 kΩ ±5%.

    The digits give 129; ×10 gives 1290 Ω. Final gold means ±5%.

  11. Карта 11

    Въпрос

    In the tolerance position of a conventional resistor code, what does red mean?

    Отговор

    ±2%.

    Read the band by its role: red can mean a digit, a multiplier, or a tolerance.

  12. Карта 12

    Въпрос

    Express 0.24 MΩ in kΩ.

    Отговор

    240 kΩ.

    One megaohm is 1000 kiloohms: 0.24 × 1000 = 240.

  13. Карта 13

    Въпрос

    In the multiplier position of a conventional resistor code, what factor does silver mean?

    Отговор

    ×0.01.

    Divide the significant-digit number by 100.

  14. Карта 14

    Въпрос

    Conventional 4-band code, read left to right: violet–white–gold–silver. Nominal resistance and tolerance?

    Отговор

    7.9 Ω ±10%.

    The digits give 79; gold multiplies by 0.1. Final silver means ±10%.

  15. Карта 15

    Въпрос

    A conventional 5-band resistor ends with a gold band. Does having five bands make its tolerance ±1%?

    Отговор

    No. Its final gold band means ±5%.

    Band count changes the number of significant digits. It does not replace the tolerance band.

  16. Карта 16

    Въпрос

    Conventional 4-band code for 820 Ω ±2%, written left to right?

    Отговор

    Gray–red–brown–red.

    82 × 10 = 820 Ω. The last red band specifies ±2%.

  17. Карта 17

    Въпрос

    In the tolerance position of a conventional resistor code, what does brown mean?

    Отговор

    ±1%.

    A brown tolerance band means one percent, not one ohm.

  18. Карта 18

    Въпрос

    Conventional 4-band code, read left to right: yellow–blue–silver–gold. Nominal resistance and tolerance?

    Отговор

    0.46 Ω ±5%.

    The digits give 46; silver multiplies by 0.01. Final gold means ±5%.

  19. Карта 19

    Въпрос

    Conventional 5-band code for 64.2 kΩ ±1%, written left to right?

    Отговор

    Blue–yellow–red–red–brown.

    642 × 100 = 64,200 Ω. Final brown specifies ±1%.

  20. Карта 20

    Въпрос

    For a nominal 1200 Ω resistor with ±5% tolerance, what is the nominal tolerance interval?

    Отговор

    1140–1260 Ω, including both endpoints.

    5% of 1200 Ω is 60 Ω; subtract and add 60 Ω.

  21. Карта 21

    Въпрос

    In the multiplier position of a conventional resistor code, what factor does violet mean?

    Отговор

    ×10,000,000.

    That is ten million, or 10⁷.

  22. Карта 22

    Въпрос

    Conventional 4-band code, read left to right: blue–brown–yellow–brown. Nominal resistance and tolerance?

    Отговор

    610 kΩ ±1%.

    61 × 10,000 = 610,000 Ω. Final brown means ±1%.

  23. Карта 23

    Въпрос

    Conventional 4-band code for 9.1 Ω ±10%, written left to right?

    Отговор

    White–brown–gold–silver.

    91 × 0.1 = 9.1 Ω. Final silver specifies ±10%.

  24. Карта 24

    Въпрос

    For a nominal 75 Ω resistor with ±2% tolerance, what is the nominal tolerance interval?

    Отговор

    73.5–76.5 Ω, including both endpoints.

    2% of 75 Ω is 1.5 Ω.

  25. Карта 25

    Въпрос

    In the multiplier position of a conventional resistor code, what factor does white mean?

    Отговор

    ×1,000,000,000.

    That is one billion, or 10⁹.

  26. Карта 26

    Въпрос

    Conventional 5-band code, read left to right: green–orange–black–green–red. Nominal resistance and tolerance?

    Отговор

    53 MΩ ±2%.

    530 × 100,000 = 53,000,000 Ω. Final red means ±2%.

  27. Карта 27

    Въпрос

    Conventional 5-band code for 3.16 Ω ±1%, written left to right?

    Отговор

    Orange–brown–blue–silver–brown.

    316 × 0.01 = 3.16 Ω. Final brown specifies ±1%.

  28. Карта 28

    Въпрос

    For a nominal 0.82 Ω resistor with ±5% tolerance, what is the nominal tolerance interval without rounding?

    Отговор

    0.779–0.861 Ω, including both endpoints.

    The deviation is 0.82 × 0.05 = 0.041 Ω.

  29. Карта 29

    Въпрос

    In the multiplier position of a conventional resistor code, what factor does gray (grey) mean?

    Отговор

    ×100,000,000.

    That is one hundred million, or 10⁸.

  30. Карта 30

    Въпрос

    Conventional 4-band code, read left to right: brown–gray–blue–gold. Nominal resistance and tolerance?

    Отговор

    18 MΩ ±5%.

    18 × 1,000,000 = 18,000,000 Ω. Final gold means ±5%.

  31. Карта 31

    Въпрос

    In the nominal interval model, a resistor is 250 Ω ±10%. Is an exact hypothetical value of 275 Ω inside, on a boundary, or outside?

    Отговор

    On the upper boundary, so it is included.

    The interval is 225–275 Ω. This exact-number exercise ignores measurement uncertainty.

  32. Карта 32

    Въпрос

    Conventional 4-band code for 36 MΩ ±5%, written left to right?

    Отговор

    Orange–blue–blue–gold.

    36 × 1,000,000 = 36 MΩ. Final gold specifies ±5%.

  33. Карта 33

    Въпрос

    For a nominal 2.4 kΩ resistor with ±1% tolerance, what is the nominal tolerance interval in kΩ?

    Отговор

    2.376–2.424 kΩ, including both endpoints.

    The deviation is 0.024 kΩ. Keep the same unit throughout.

  34. Карта 34

    Въпрос

    Conventional 4-band code, read left to right: blue–black–orange–gold. A learner gets 0 Ω because black is 0. Correct the nominal value.

    Отговор

    60 kΩ.

    Blue–black forms 60, then orange multiplies by 1000. The zero is a digit inside 60.

  35. Карта 35

    Въпрос

    In the nominal interval model, a resistor is 2000 Ω ±2%. Is an exact hypothetical value of 2041 Ω inside or outside?

    Отговор

    Outside.

    The inclusive interval is 1960–2040 Ω. The hypothetical value is 1 Ω above the upper limit; measurement uncertainty is outside this exercise.

  36. Карта 36

    Въпрос

    Conventional 5-band code for 91.3 MΩ ±2%, written left to right?

    Отговор

    White–brown–orange–green–red.

    913 × 100,000 = 91.3 MΩ. Final red specifies ±2%.

  37. Карта 37

    Въпрос

    Conventional 4-band code, read left to right: green–red–gold–brown. A learner treats gold as the tolerance. Give the correct nominal resistance and tolerance.

    Отговор

    5.2 Ω ±1%.

    Gold is the third band, so it multiplies 52 by 0.1. Final brown supplies ±1%.

  38. Карта 38

    Въпрос

    A nominal 6.8 Ω resistor has ±1% tolerance. A learner rounds the deviation to 0.07 Ω before finding the limits. What is the unrounded interval?

    Отговор

    6.732–6.868 Ω.

    Use the exact deviation, 6.8 × 0.01 = 0.068 Ω, before subtracting and adding.

  39. Карта 39

    Въпрос

    A conventional 5-band code is listed from one end: brown–green–black–brown–red. Reading direction and physical spacing are unknown. Is one nominal resistance uniquely determined?

    Отговор

    No. Both directions give valid readings.

    As listed: 150 × 10 = 1500 Ω ±2%.

    Reversed: red–brown–black–green–brown gives 210 × 100,000 = 21 MΩ ±1%. More orientation evidence is needed.

  40. Карта 40

    Въпрос

    A calculation gives 72,000 Ω. A learner writes 72 MΩ. Correct the unit conversion.

    Отговор

    72 kΩ, or 0.072 MΩ.

    Divide ohms by 1000 for kiloohms, or by 1,000,000 for megaohms.

  41. Карта 41

    Въпрос

    Does a ±5% resistor tolerance mean there is a 95% probability that its resistance lies in the nominal interval?

    Отговор

    No. Tolerance is not a probability distribution.

    It specifies a relative allowed deviation under the applicable specifications. The percentage alone does not give probabilities or cover every operating condition.

  42. Карта 42

    Въпрос

    Does seeing five bands on an unfamiliar real component prove that it uses the conventional 5-band resistor code?

    Отговор

    No. Confirm the component and marking scheme.

    These cards assume conventional resistor markings. Special manufacturer schemes and six-band temperature-coefficient markings are outside this deck.

A centered beige axial resistor with brown, green, orange and gold bands on a dark blue surface.

42 карти

Resistor Color Code Flashcards: 4 Bands, 5 Bands & Tolerance

Учете с това тесте безплатно

Nibomo се отваря, за да започнете да учите.