Loaded Voltage Divider Practice With Two Meters
Two 1 MΩ resistors across a 12 V supply put their midpoint at 6 V. Connect a voltmeter with 1 MΩ of input resistance and the model predicts a reading of 4 V. Swap in a 10 MΩ meter and it predicts about 5.71 V. Each meter draws current through its input, so connecting it changes the voltage you wanted to measure.

Put the meter in the sketch
For these paper problems, use an ideal DC source, zero-resistance wires, and exact resistor values. Draw the voltmeter as a single resistance, R_meter. Its reading equals the voltage across that resistance.
A --[R_top]-- B --[R_bottom]-- C
| |
+---[R_meter]----+
The supply holds node A at +12 V relative to node C, the 0 V reference. The output is the voltage from B to C. The meter and R_bottom both connect between B and C, so they are in parallel. With the meter branch removed and both divider resistors still connected, the voltage from B to C is the open-circuit output voltage. OpenStax on connecting a voltmeter
Before calculating, predict how the reading changes as the meter's input resistance goes up. With the 1 MΩ meter attached, the two 1 MΩ resistances between B and C combine to give 1 × 1 / (1 + 1) = 0.5 MΩ. The bottom leg now gets a smaller share of the supply voltage. The divider formula gives 12 V × 0.5 / (1 + 0.5) = 4 V. Series and parallel circuit practice
| Meter input resistance | Effective bottom resistance | Predicted output | Drop from the open-circuit 6 V |
|---|---|---|---|
| Meter disconnected | 1 MΩ | 6 V | 0% |
| 1 MΩ | 0.5 MΩ | 4 V | 33.33% |
| 10 MΩ | 10/11 MΩ | 40/7 V ≈ 5.71 V | 4.76% |
This change in the output is the voltmeter loading effect. As the meter resistance rises, it draws less current and the output approaches the open-circuit 6 V.
How much input resistance is enough?
Seen from B and C, the divider behaves like an ideal voltage source V_open in series with an output resistance R_out. This is its Thévenin equivalent. To find R_out, remove the meter and replace the ideal voltage source with a wire in the sketch. This joins A and C, leaving both resistors connected across the same two nodes. Their parallel resistance is R_out. With two 1 MΩ resistors, R_out = 0.5 MΩ.
Connect the meter across the equivalent circuit's output. Now R_out and R_meter form a divider across V_open. The share of V_open lost to loading is the share that drops across R_out.
V_meter = V_open × R_meter / (R_out + R_meter)
Loading error = (V_open − V_meter) / V_open
= R_out / (R_out + R_meter)
Call the maximum allowed loading error e and write it as a fraction, so 1% is 0.01. Set R_out / (R_out + R_meter) ≤ e and multiply by R_out + R_meter to get R_out ≤ e × (R_out + R_meter). Rearranging gives R_meter ≥ R_out × (1 − e) / e.
A 1% loading error limit calls for at least 99 times the output resistance. For the original divider, that's 99 × 0.5 MΩ = 49.5 MΩ. At that minimum, the reading is 5.94 V, exactly 1% below the open-circuit 6 V. A requirement of less than 1% calls for more than 49.5 MΩ.
For a real meter, check the input resistance for the DC voltage range you'll use. It can vary by range. The 1% budget here covers loading from input resistance alone. Other effects, such as input bias current, can also change the reading. Fluke 8842A instruction manual, sections 4-3 and 4-4 (PDF)
Four problems to solve on paper
- Work backward from a low reading. The original 12 V divider with two 1 MΩ resistors reads exactly 5 V with an unknown meter attached. What is the meter's input resistance in this model?
- Change both resistors. Build a second 12 V divider on paper with two 10 kΩ resistors. What is each divider's open-circuit output voltage? What does a 1 MΩ meter read on the 10 kΩ divider? How much current does each divider draw from its supply with the meter disconnected?
- Choose a meter for a different split. A 12 V divider has a 1 MΩ top resistor and a 2 MΩ bottom resistor. The allowed loading error is 3% or less. Which of the two meters meets the limit, the 20 MΩ meter or the 25 MΩ meter?
- Keep the meter and redesign the divider. A 10 MΩ meter must read the midpoint of a 12 V divider with at most 0.5% loading error. The divider uses two equal resistors. How large can each one be? Would two 100 kΩ resistors work?
Worked answers
- 2.5 MΩ. The open-circuit output is 6 V, so a reading of 5 V gives an error fraction of
1/6. The error formula givesR_out + R_meter = 6 × 0.5 MΩ = 3 MΩ. Subtract the divider's 0.5 MΩ output resistance to find the meter's input resistance. - Both open-circuit outputs are 6 V. The 10 kΩ pair has
R_out = 5 kΩ. Express the meter's 1 MΩ as 1,000 kΩ to get the reading6 V × 1,000 / (5 + 1,000) = 400/67 V ≈ 5.97 V. With the meter disconnected, the 10 kΩ pair draws12 V / 20 kΩ = 0.6 mA, and the 1 MΩ pair draws12 V / 2 MΩ = 6 µA. Scaling both resistors down cuts the loading error at the cost of higher supply current. - The 25 MΩ meter meets the limit. The resistors in parallel give
R_out = 2/3 MΩ. The 3% limit calls for at least(2/3) × (0.97/0.03) MΩ ≈ 21.56 MΩ. Substituting the two meter resistances into the error formula gives about 3.23% for the 20 MΩ meter and 2.60% for the 25 MΩ meter. - Each resistor can be at most
20/199 MΩ, about 100.50 kΩ. A 0.5% limit meanse = 0.005, so the meter resistance must be at least 199 timesR_out. Two equal resistors in parallel giveR_outequal to half of either resistor's value. Each resistor can therefore be at most2 × 10 MΩ / 199. Two 100 kΩ resistors giveR_out = 50 kΩand a loading error of50 / (50 + 10,000) ≈ 0.498%. The pair meets the limit.
Save the step you had to look up
Cover the answers and try these prompts tomorrow before solving another example.
| Prompt | Answer |
|---|---|
| Which resistor shares both nodes with the meter in the sketch? | R_bottom. Both connect between B and C, so the meter's input resistance goes in parallel with it. |
| How high must the meter's input resistance be for a loading error of 1% or less? | At least 99 times the divider's output resistance. |
AI assisted with drafting and editing the article and exercises. The cover illustration is AI-generated.