Rate Law Flashcards: Method of Initial Rates

Use 30 flashcards to pick trial pairs, find reaction orders and rate constant units, and check a fitted rate law against new initial-rate data.

Despre acest pachet

Practice deriving rate laws from initial-rate data with one- and two-reactant examples. Start by choosing a pair of trials that isolates one reactant. Use rate and concentration ratios to find its order, then combine the orders into a rate law and work out the rate constant and its units. You’ll predict rates from the law, work backward from a target rate change, and see whether a fitted law holds up against an extra trial.

Using integrated rate laws to track concentrations over time is a separate practice task. Each prediction here uses a single trial. Rebuilding a full table would repeat that calculation across rows.

The practice data are fictional and use exact values. The original wording, examples, and card arrangement are offered under CC0 1.0.

Fișele din acest pachet

  1. Fișa 1

    Întrebare

    Which pair of trials isolates the order in A? All three trials are at the same temperature.

    Trial 1 has [A]=0.20 M[A]=0.20\,\mathrm{M} and [B]=0.10 M[B]=0.10\,\mathrm{M}.

    Trial 2 has [A]=0.60 M[A]=0.60\,\mathrm{M} and [B]=0.10 M[B]=0.10\,\mathrm{M}.

    Trial 3 has [A]=0.20 M[A]=0.20\,\mathrm{M} and [B]=0.40 M[B]=0.40\,\mathrm{M}.

    Răspuns

    Trials 1 and 2. They have different [A][A] values and the same [B][B].

  2. Fișa 2

    Întrebare

    At fixed [B][B] and temperature, multiplying [A][A] by 5 multiplies the initial rate by 5. What is the order in A?

    Răspuns

    First order. The rate factor is 515^1.

  3. Fișa 3

    Întrebare

    A reaction is first order in A and third order in B. Write its rate law using rate constant kk.

    Răspuns

    r=k[A][B]3r=k[A][B]^3. Each reactant’s order is its concentration exponent.

  4. Fișa 4

    Întrebare

    A rate law is r=k[A]2[B]2r=k[A]^2[B]^2. What is its overall order?

    Răspuns

    Fourth order. The concentration exponents add up to 2+2=42+2=4.

  5. Fișa 5

    Întrebare

    Trial 1 runs at 20 °C and trial 2 runs at 30 °C. Their [B][B] values match and their [A][A] values differ. What prevents this pair from isolating the order in A?

    Răspuns

    The temperature change can change kk. Use trials at the same temperature so the rate comparison can isolate A.

  6. Fișa 6

    Întrebare

    At fixed [A][A] and temperature, quadrupling [B][B] leaves the initial rate unchanged. What is the order in B?

    Răspuns

    Zero order. The rate factor is 1=401=4^0.

  7. Fișa 7

    Întrebare

    For r=k[A]r=k[A], the initial rate is 0.064 M/s0.064\,\mathrm{M/s} at [A]=0.16 M[A]=0.16\,\mathrm{M}. What is kk?

    Răspuns

    0.40 s−10.40\,\mathrm{s}^{-1}. Divide the rate by [A][A], giving 0.064/0.16=0.400.064/0.16=0.40.

  8. Fișa 8

    Întrebare

    For r=k[A]2[B]r=k[A]^2[B], [A][A] increases by a factor of 1.5 while [B][B] stays fixed. By what factor does the initial rate change?

    Răspuns

    The rate increases by a factor of 2.252.25. Square the concentration factor, 1.52=2.251.5^2=2.25.

  9. Fișa 9

    Întrebare

    What are the units of kk for a reaction of overall order pp if the rate is in M/s and the concentrations are in molarity (M)?

    Răspuns

    M1−p s−1\mathrm{M}^{1-p}\,\mathrm{s}^{-1}. Divide the rate units by Mp\mathrm{M}^{p}.

  10. Fișa 10

    Întrebare

    At fixed [B][B] and temperature, tripling [A][A] changes the initial rate from 0.007 M/s0.007\,\mathrm{M/s} to 0.063 M/s0.063\,\mathrm{M/s}. What is the order in A?

    Răspuns

    Second order. The rate factor is 0.063/0.007=9=320.063/0.007=9=3^2.

  11. Fișa 11

    Întrebare

    At fixed [B][B], trial 1 has [A]=0.08 M[A]=0.08\,\mathrm{M} and trial 2 has [A]=0.24 M[A]=0.24\,\mathrm{M}. Which concentration factor matches the rate ratio r2/r1r_2/r_1?

    Răspuns

    0.24/0.08=30.24/0.08=3. Put the same trial in the numerator of both ratios.

  12. Fișa 12

    Întrebare

    For r=k[A]2[B]r=k[A]^2[B], [A][A] is halved and [B][B] is tripled. What is the new initial rate as a fraction of the original?

    Răspuns

    3/43/4 of the original rate. Multiply the two rate factors, (1/2)2×3=3/4(1/2)^2\times3=3/4.

  13. Fișa 13

    Întrebare

    For r=k[A][B]2r=k[A][B]^2, the initial rate is 0.054 M/s0.054\,\mathrm{M/s} at [A]=0.30 M[A]=0.30\,\mathrm{M} and [B]=0.20 M[B]=0.20\,\mathrm{M}. What is kk?

    Răspuns

    4.5 M−2 s−14.5\,\mathrm{M}^{-2}\,\mathrm{s}^{-1}. Dividing the rate by [A][B]2[A][B]^2 gives 0.054/(0.30×0.202)=4.50.054/(0.30\times0.20^2)=4.5.

  14. Fișa 14

    Întrebare

    At the same temperature, both [A][A] and [B][B] double and the initial rate becomes eight times as large. What does this pair reveal about the orders in r=k[A]m[B]nr=k[A]^m[B]^n?

    Răspuns

    It gives the sum m+n=3m+n=3. Both m=1,n=2m=1,n=2 and m=2,n=1m=2,n=1 give 2m×2n=82^m\times2^n=8, so more data are needed to find the individual orders.

  15. Fișa 15

    Întrebare

    At fixed [A][A] and temperature, increasing [B][B] by a factor of 9 triples the initial rate. What is the order in B?

    Răspuns

    One-half. The rate factor is 3=91/23=9^{1/2}.

  16. Fișa 16

    Întrebare

    A reaction is second order in A and zero order in B. What is the simplified rate law for positive concentrations?

    Răspuns

    r=k[A]2r=k[A]^2. The B factor is [B]0=1[B]^0=1.

  17. Fișa 17

    Întrebare

    A zero-order reaction has an initial rate in M/s. What units does kk have?

    Răspuns

    M/s. The law simplifies to r=kr=k, so the rate and kk have the same units.

  18. Fișa 18

    Întrebare

    At the same temperature, trial 2 doubles [A][A] and halves [B][B] relative to trial 1. Both trials give the same initial rate. Could the reaction be first order in both A and B?

    Răspuns

    Yes. For r=k[A][B]r=k[A][B], the two factors cancel because 2×(1/2)=12\times(1/2)=1.

  19. Fișa 19

    Întrebare

    For r=k[A]2[B]r=k[A]^2[B], what factor should multiply [A][A] to make the initial rate one-ninth as large while [B][B] stays fixed?

    Răspuns

    1/31/3. The concentration factor squared must be 1/91/9.

  20. Fișa 20

    Întrebare

    At fixed [B][B] and temperature, multiplying [A][A] by 4 multiplies the initial rate by 5. What exact expression gives the order mm in A?

    Răspuns

    m=ln⁡(5)/ln⁡(4)m=\ln(5)/\ln(4), about 1.161.16. Take logs of 4m=54^m=5 and solve for mm.

  21. Fișa 21

    Întrebare

    The law is r=k[A][B]1/2r=k[A][B]^{1/2} with rate in M/s and concentrations in M. What are the units of kk?

    Răspuns

    M−1/2 s−1\mathrm{M}^{-1/2}\,\mathrm{s}^{-1}. The overall order is 3/23/2, so the molarity exponent in kk is 1−3/2=−1/21-3/2=-1/2.

  22. Fișa 22

    Întrebare

    The overall balanced equation is 2 A+B→C2\,\mathrm{A}+\mathrm{B}\rightarrow\mathrm{C}. Does the coefficient 2 establish the order in A?

    Răspuns

    No. The overall equation gives the stoichiometry. Use kinetic data to determine the rate law’s exponent for A.

  23. Fișa 23

    Întrebare

    Do these trials at the same temperature give the same fitted kk for r=k[A]2r=k[A]^2?

    Trial 1 has [A]=0.20 M[A]=0.20\,\mathrm{M} and initial rate 0.016 M/s0.016\,\mathrm{M/s}.

    Trial 2 has [A]=0.60 M[A]=0.60\,\mathrm{M} and initial rate 0.144 M/s0.144\,\mathrm{M/s}.

    Răspuns

    Yes. Both 0.016/0.2020.016/0.20^2 and 0.144/0.6020.144/0.60^2 give k=0.40 M−1 s−1k=0.40\,\mathrm{M}^{-1}\,\mathrm{s}^{-1}.

  24. Fișa 24

    Întrebare

    Two trials at the same temperature follow r=k[A]m[B]r=k[A]^m[B]. The second trial triples [A][A], doubles [B][B], and gives an initial rate 18 times as large. What is the order in A?

    Răspuns

    Second order. Divide out B’s factor of 2. The remaining factor is 18/2=9=3218/2=9=3^2.

  25. Fișa 25

    Întrebare

    These three trials are at the same temperature. What power-law expression fits the initial rates? Leave kk as a symbol.

    Trial 1 has [A]=0.10 M[A]=0.10\,\mathrm{M}, [B]=0.25 M[B]=0.25\,\mathrm{M}, and initial rate 0.020 M/s0.020\,\mathrm{M/s}.

    Trial 2 has [A]=0.20 M[A]=0.20\,\mathrm{M}, [B]=0.25 M[B]=0.25\,\mathrm{M}, and initial rate 0.080 M/s0.080\,\mathrm{M/s}.

    Trial 3 has [A]=0.10 M[A]=0.10\,\mathrm{M}, [B]=0.75 M[B]=0.75\,\mathrm{M}, and initial rate 0.060 M/s0.060\,\mathrm{M/s}.

    Răspuns

    r=k[A]2[B]r=k[A]^2[B]. From trial 1 to 2, doubling [A][A] quadruples the rate. From trial 1 to 3, tripling [B][B] triples the rate.

  26. Fișa 26

    Întrebare

    The rate constant has units M−2 s−1\mathrm{M}^{-2}\,\mathrm{s}^{-1} when rates are in M/s and concentrations are in M. What is the overall order?

    Răspuns

    Third order. For overall order pp, the molarity exponent in kk is 1−p1-p. Here 1−p=−21-p=-2.

  27. Fișa 27

    Întrebare

    For r=k[A][B]r=k[A][B], k=0.80 M−1 s−1k=0.80\,\mathrm{M}^{-1}\,\mathrm{s}^{-1}. What initial rate does the law predict at [A]=0.20 M[A]=0.20\,\mathrm{M} and [B]=0.50 M[B]=0.50\,\mathrm{M}?

    Răspuns

    0.080 M/s0.080\,\mathrm{M/s}. Multiply kk by both concentrations, giving 0.80×0.20×0.50=0.0800.80\times0.20\times0.50=0.080.

  28. Fișa 28

    Întrebare

    A proposed law r=k[A][B]2r=k[A][B]^2 fits a reference trial with initial rate 0.032 M/s0.032\,\mathrm{M/s}. In a new trial at the same temperature, [A][A] stays fixed and [B][B] doubles. The reported initial rate is 0.096 M/s0.096\,\mathrm{M/s}. Does the law fit the new trial’s exact data?

    Răspuns

    No. Doubling [B][B] multiplies the predicted rate by 4, giving 0.128 M/s0.128\,\mathrm{M/s}. The reported rate is three times the reference rate.

  29. Fișa 29

    Întrebare

    A trial has [A]=0.16 M[A]=0.16\,\mathrm{M} and [B]=0.24 M[B]=0.24\,\mathrm{M}. Give one pair of concentrations for a second trial at the same temperature that would isolate the order in B.

    Răspuns

    One option is [A]=0.16 M[A]=0.16\,\mathrm{M} and [B]=0.48 M[B]=0.48\,\mathrm{M}. Keep [A][A] fixed and choose a different positive [B][B] at the same temperature.

  30. Fișa 30

    Întrebare

    A proposed rate law predicts every initial rate in a set of trials exactly. What can you conclude about the reaction mechanism from those data alone?

    Răspuns

    Several mechanisms could give the same rate law. The fit supports the law under the tested conditions. Identifying the mechanism requires further evidence.

Two glass vials of amber liquid beside a stopwatch on a dark teal background.

30 de fișe

Rate Law Flashcards: Method of Initial Rates

Studiază gratuit acest pachet

Nibomo se deschide ca să poți începe să studiezi.

Pachete similare